Comments on: Herbie method for Dual Overflows https://gmacreef.com/herbie-dual-overflows/ Reef Aquarium Plumbing & Design Fri, 17 Jan 2025 05:14:50 +0000 hourly 1 https://wordpress.org/?v=6.8.13 By: gmacreef https://gmacreef.com/herbie-dual-overflows/#comment-52136 Fri, 17 Jan 2025 05:14:50 +0000 http://gmacreef.com/?p=545#comment-52136 In reply to Andrew McNally.

If you are doing a siphon inside an overflow, it needs another drain in the same overflow. No getting around that. In other words you can’t have a siphon on its own.
What you described sounds like Option 3, so you would just have to consider the weir heights of each overflow. I do think you could get adequate flow in a 220 gal with only 1″ pipe.

]]>
By: Andrew McNally https://gmacreef.com/herbie-dual-overflows/#comment-41313 Sun, 21 Jul 2024 13:30:42 +0000 http://gmacreef.com/?p=545#comment-41313 Great article! Thank you for the write up.
I have a 220 72x24x30 with dual over flows in the back corners. Each over flow has two 1” bulkheads, I’m trying to prevent running the return over the back.
I would like to do 2 full siphons and only 1 emergency so the 4th could be return because what are the chances of both siphons getting clogged but still doesn’t seem safe, also thought of the balance pipe inside the tank.
Would bean animal work if I did herbie in one overflow and than other overflow would be trickle stand pipe and return? Could I get enough water turnover with 1” full siphons and 1” open channel? Thanks

]]>
By: gmacreef https://gmacreef.com/herbie-dual-overflows/#comment-25482 Tue, 21 Mar 2023 22:03:46 +0000 http://gmacreef.com/?p=545#comment-25482 In reply to Rich.

It is not advisable to Tee any of the drains – by doing so you cut the capacity in half. Not good.
The emergency drains need to have at least the same capacity as the siphon lines.
On a Herbie drain, the Emergency drain needs to be able to go into siphon mode – which just can’t happen reliably if there are two inlets on the same pipe.
For the Siphon lines, they need to be separate, discrete pipes. This is the only configuration that works because each siphon line needs to be adjusted to the flow that is running in that particular overflow that it sits in.
Thank you for commenting.

]]>
By: Rich https://gmacreef.com/herbie-dual-overflows/#comment-25335 Mon, 13 Mar 2023 06:47:37 +0000 http://gmacreef.com/?p=545#comment-25335 I just set up my 180 with dual overflows. I ran both 1” siphons down at 1/2” per foot into a “y” then through a gate valve. Then I ran both emergency drains at the same 1/2” per foot into a “y” then into the sump directly. Every measurement is identical into the standpipes and “y’s”, tank is dead nuts level. From this article, my setup isn’t gonna work. How accurate is that.

]]>
By: gmacreef https://gmacreef.com/herbie-dual-overflows/#comment-20847 Wed, 25 May 2022 23:30:34 +0000 http://gmacreef.com/?p=545#comment-20847 In reply to Reef Keeper.

The 3/4″ main drain with a 1″ emergency is definitely sufficient. I currently have a 40 cube with 15 gal sump that has those same drain sizes. I have a Jebao DCQ-3500 that runs around 55% mostly because I want it silent. The drain can easily handle it at full power though so I think you are good.

]]>